I fixed it with some high temp tape but i am looking for a more permanent solution. The top of the chamber is opened so that the hot gasses from the burning process can be vented directly to the exterior through the metal flue pipe. Highefficiency furnace combustion problems the spruce. Flue collector box front cover 20170904as quantity add to cart. The your heat exchanger is cracked so your furnace must be. Hvac goodman collector box 1 plainfield, il youtube. I have a goodman gmpn1205 the combustion blower comes on. It is ideal to replace with your cracked or damaged collector boxes. As flue collector boxes may get cracked after years of use, this 21 flue collector box will serve as an exact fit replacement for the following models. The 2820007s replaces outdated part number 2820007. Hvac goodman furnace flue collector replacment step by step.
Cracks in furnaces all about homes by john schnedier q. Heat exchanger failure diagnosis, goodman gmp model. This is the second leak from the collector box, first time the gasket was replaced. It keeps the flue from causing a vacuum and putting out the. Hvac goodman collector box 4 plainfield, il youtube. Goodman gmp1003 furnace parts manufacturerapproved parts for a proper fit every time. Johnstone supply is a leading wholesale distributor for multiple leading brands of hvacr equipment, parts and supplies available and instock at local branches. The ahri reference number has been copied to your clipboard. The 485s flue collector box is an oem standard replacement part designed for use in an array of goodman, amana, and janitrol units. Flue condensation problems why gas heating safety 101.
This collector box comes directly from the factory and assures superior quality. Images are for illustration, products subject to manufacturer revision. We have manufactured and supplied single wall and twin wall gas flue collector boxes for over 30 years to the chimney flue industry. This is a guaranteed genuine goodman oem replacement for several goodman, amana, and janitrol units. The condensate trap is absolutely mandatory for a highefficiency gas furnace. Jan 27, 2011 hvac goodman collector box 5 plainfield, il. In order to prepare for the winter, i had my forced air furnace serviced by a repairman.
The smaller metal box inside the furnace cabinet is the heat exchanger. We have manuals, guides and of course parts for common gms91155dxap1256806f problems. Flue gas collector gas flue boxes flue manufacturer. May 24, 20 what is the purpose of the furnace collector box. Chimney flue repair may be necessary if you have clay flue tiles inside your masonary chimney that are cracked or busted.
Company 485s collection box is a replacement part and is compatible with the following models. This 14 flue collector box with gasket is a practical asset for any house or heating system. Do any of you guys know if the replacement hx comes with the collector box installed or is the old one reused. The combustion chamber is the metal box that surrounds the gas burners serving the furnace. Flue collector box 253s goodmanamana this is a guaranteed genuine goodman oem replacement for several goodman, amana, and janitrol units. Flue boxes often get cracked through years of usage and require a. Paste the number into the search box and click search to obtain the certificate. A partially clogged flue vent condensate line, or a clog at the condensate collector box. Flue collector box 2820007s goodmanamana goodman repair. Industrial stores carries quality name brand flue collector boxes for all manufacturers of furnaces. Jan 26, 2010 i have a goodman gmpn1205 the combustion blower comes on i have good exhaust out of the blower but it still goes off on a safety of 3 blinking lights.
Goodmanamana 22309501 furnace flue pipe furnace flue pipe. Continue to pry around collector box until collector box can be removed. The amanagoodman 2820004s flue collector box is a genuine oem flue collector box for various goodman, amana, and janitrol units. Goodmanamana 20171003as collector box collector box. Furthermore, if you have this problem or see it on your furnace heating system please consult a professional. Safety considerations installing and servicing heating equipment can be hazardous due to gas and electrical components. These units act as drain pans that collect water and condensate for active furnaces and flues. Since its a goodman get 2 collector boxes, a couple pressure switches, inducer motor, flame sensor and circuit board for repairs it will need in the next year or so. However, the repairman stated that there was a crack in the combustion chamber, and the furnace needed to be replaced. After seeing a cracked collector box come from a unit where it had to be changed, i was struck with curiousity in. Whether you are in need of a single gasket or an entire set, we have you covered. Collector box replacement kit installation instructions part no. Read the entire instruction manual before starting the installation.
All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other goodman product. The amana goodman 250s flue collector is a highquality genuine goodman oem replacement for several goodman, amana, and janitrol units. In addition, you should check for cracked or broken hoses running. Collector box replacement kit installation instructions. Condensate drainage in a high efficiency gas furnace hvac. Mar 08, 2019 the secondary heat exchanger outlet is sealed inside a plastic part called the collector box, which is designed to collect the condensate and drain it out. But while i was in there watching it before i closed up the cabinet to make sure all looked well i noticed that the flue collector box was pretty hot to the touch, but the furnace was. The plastic did not break into pieces rather the nipple just pulled out with a small plastic border around it.
This 20170904as is a guaranteed genuine goodman oem replacement for several goodman, amana, and janitrol units. Made of best grade materials, it will ensure reliable performance for years to come. This 251s flue collector is a guaranteed genuine goodman oem replacement for several goodman, amana, and janitrol units. Seller assumes all responsibility for this listing. I noticed a crack in the flue collector box and replaced that and it still wont fire.
It seats back snugly in place when hand held there. Feb 01, 2014 a service man attempting to remove the rubber hose on my goodman gmpn804 gas furnace broke the water drain nipple loose in the flue collector box. The unit is a 1994 goodman which otherwise works well. Goodman amana 20171003as collector box collector box. This item will ship to united states, but the seller has not specified shipping options. This is the second leak from the collector box, first time the gasket was replaced with rtv silicone, now a year later the rtv gasket sprung a leak. Made of quality metal, it is going to serve your heating system for many years to come. A x89733 2820006s flue collector box assy 21 a x89734 2820004s flue collector box 14 a x89735 2820005s flue collector box assy 17. Flue collector boxes often become cracked through years of usage. After seeing a cracked collector box come from a unit where it had to be changed, i was struck with curiousity in its purpose, never really understood that, can someone please help. Hvac goodman collector box 5 plainfield, il youtube. Flue collector box 253s goodmanamana goodman repair. We also have installation guides, diagrams and manuals to help you along the way.
If you are a stockist or flue manufacturer requiring your own designs then contact us for a quote as we are also able to offer a bespoke service. Designed for optimal performance and durability, the amana goodman 252s flue collector is a quality oem grade replacement part to be used in various goodman, amana, and janitrol unit. Acs90904cxa, ams90904cxa, gcs90904cxa, gks90904cx, gms90904cxa, guca090ax40, guca090bx40, guca090cx40 and p1252604f. Home heat exchangers heat exchanger collector boxes.
It is perfect for use with gmpn0403, gmpn0603, gsm0603, and gsms0603 model series. Company 20170902as front cover is a replacement part and is compatible with the following models. We have manuals, guides and of course parts for common gmnt0804b problems. This is a requirement, is part of the fuel gas codes and is ultimately not negotiable. A partially clogged flue vent condensate line, or a clog at the condensate collector box near the inducer fan, will often trip the furnaces pressure switch. We replaced inducer assembly 1 week ago and the little sensor has to be bypassed to keep furnace running.
Find all the parts you need for your goodman furnace gms91155dxap1256806f at. The gaskets ensure no leakage of flue gases while safely ducting them out of the heating appliance to. When the furnace is turned on, the burners light, creating flames that heat the chamber. I usually find them cracked like this same furnace, found a nice long crack in the primary hx. Is it easy to remove the box now that is is sealed in. Jan 23, 2020 in 3 months time we replaced collector box 4 times, had to replace the inducer assembly 3 times within 2 years and had to replace the blower motor. The water is collecting in the flue collector box, which is mounted to the. You are being redirected to the ahri directory website. A furnace with a cracked heat exchanger will definitely produce carbon monoxide and poses.
A service man attempting to remove the rubber hose on my goodman. Remove screws securing collector box to front of cell panel. Here are some signs that may indicate your issue is a cracked or malfunctioning heat exchanger. Make sure your goodman furnace is ready for winter to arrive with high quality gaskets and seals from repair clinic.
Please check the box below to confirm you are aware that this item is for non. If the condensate drain is blocked by debris or frozen condensate, or it simply drains improperly, the pressure switch may open, preventing ignition. Work knife or scraper along collector box to break silicone seal. Blxecky diy 5d diamond painting cross stitch crafts kit, 5 sets of splicing paintings. Goodman gas furnace cracked heat exchanger double change out duration. If you have a heat exchanger crack, you need to replace the heat exchanger or the furnace. This product does not comply with the safe drinking water act, which requires that products used in any system providing water for human consumption drinking or cooking to meet lowlead standards. But while i was in there watching it before i closed up the cabinet to make sure all looked well i noticed that the flue collector box was pretty hot to the touch, but the furnace was working to get the upstairs back up to thermostat temp and to be honest i dont know if that is normal kinda makes sense, heat is recirculating just behind it. Use putty knife or automotivetype gasket scraper and carefully pry up on collector box assembly where it meets cell panel. This 21 flue collector is a great alternative to the original cracked collector box after years of usage.
Keep your eye on goodman s gmpn units for cracked collector box s. It is loud and once again we are having problems with it. My concern is the fact that mechanics walk past other potential carbon monoxide poisoning issues to get to heat exchanger inspection. Find all the parts you need for your goodman furnace gmnt0804b at. The 486s replaces outdated part numbers 486 and 482. Only trained personnel should install or service heating. I have a goodman gmn0804 90% gas hot air furnace, about 15 years old. Click on shop parts, or select the kind of product youre working with on the left and well help you find the right part. If a busted tile is located, or you see a mortar joint between the tiles beginning to fail, its important to repair it as soon as possible. Designed to match best quality standards, the amanagoodman 486s flue collector box is an oem grade replacement part for use with a variety of goodman and amana units. I have a goodman gmpn1205 the combustion blower comes on i. Over time, cracks in the exchanger can result in carbon monoxide leaks. With johnstone, you can stay current on product and technology changes, in addition to programs that make it easy for the contractor.
719 264 1324 1550 1112 255 242 948 1016 148 1162 1426 348 1291 1329 1292 702 1376 1096 1203 1279 1248 770 1026 71 1417 571 23 941 294 1493 868